Sifto Ghost Buster
- Introduction
- Application (Sample 1)
- Application (Sample 2)
- Advantages & limitations
- Ordering Info
- Sifto Ghost Buster Column can very efficiently absorb the impurities from mobile phase and eliminates the risk of ghost peaks interfering with target peaks and make the gradient analysis reliable.
- Longer Column life (Main column) when used with Sifto Ghost Buster Column.
- Stable over a wide range of pH, organic solvents and aqueous buffers.
- Add Graphs
Advantages
- Remove ghost peaks efficiently
- Compatible with water and organic solvents
- Easy to install
- Trace detection
- Can be used multiple times
- Ionparing solvent – If ion pairing reagents are used in the analysis, it is possible that the reagents may be retained by the Ghost Buster column, impacting the analysis retention time and peak shape.
- Amines additives – If amines additives, such as ammonia and triethylamine, are used in the solvent the peakshape may change.
- It should be noted that not all impurities can be removed from the mobile phase.
- It is not recommended to flush the Ghost Buster column with 100% water for a long time.
- GhostBuster column is installed between the gradient mixer and the sampler. If it is installed like a guard column, target peaks may disappear.
- GhostBuster column’s service life differs by analysis conditions, mobile phase and its purity.
- New column is recommended when result is not ideal.
Sr no. | Part No | Dimensions |
---|---|---|
1 | SFT.GSTB.4650 | 50mmX4.6mm |
2 | SFT.GSTB.4630 | 30mmX4.6mm |
3 | SFT.GSTB.4621 | 50mmX2.1mm |
4 | SFT.GSTB.3021 | 30mmX2.0mm |
Customized dimension can be made available on customer request, subject to the availability.
Introduction
- Sifto Ghost Buster Column can very efficiently absorb the impurities from mobile phase and eliminates the risk of ghost peaks interfering with target peaks and make the gradient analysis reliable.
- Longer Column life (Main column) when used with Sifto Ghost Buster Column.
- Stable over a wide range of pH, organic solvents and aqueous buffers.
- Add Graphs
Advantages & limitations
Advantages
- Remove ghost peaks efficiently
- Compatible with water and organic solvents
- Easy to install
- Trace detection
- Can be used multiple times
Limitations
- Ionparing solvent – If ion pairing reagents are used in the analysis, it is possible that the reagents may be retained by the Ghost Buster column, impacting the analysis retention time and peak shape.
- Amines additives – If amines additives, such as ammonia and triethylamine, are used in the solvent the peakshape may change.
Note:
- It should be noted that not all impurities can be removed from the mobile phase.
- It is not recommended to flush the Ghost Buster column with 100% water for a long time.
- GhostBuster column is installed between the gradient mixer and the sampler. If it is installed like a guard column, target peaks may disappear.
- GhostBuster column’s service life differs by analysis conditions, mobile phase and its purity.
- New column is recommended when result is not ideal.
Ordering Info
Sr no. | Part No | Dimensions |
---|---|---|
1 | SFT.GSTB.4650 | 50mmX4.6mm |
2 | SFT.GSTB.4630 | 30mmX4.6mm |
3 | SFT.GSTB.4621 | 50mmX2.1mm |
4 | SFT.GSTB.3021 | 30mmX2.0mm |