Sifto Ghost Buster

  • Introduction
  • Application (Sample 1)
  • Application (Sample 2)
  • Advantages & limitations
  • Ordering Info
  • Sifto Ghost Buster Column can very efficiently absorb the impurities from mobile phase and eliminates the risk of ghost peaks interfering with target peaks and make the gradient analysis reliable.
  • Longer Column life (Main column) when used with Sifto Ghost Buster Column.
  • Stable over a wide range of pH, organic solvents and aqueous buffers.
  • Add Graphs

 

Advantages 
  1. Remove ghost peaks efficiently
  2. Compatible with water and organic solvents
  3. Easy to install
  4. Trace detection
  5. Can be used multiple times
Limitations
  1. Ionparing solvent - If ion pairing reagents are used in the analysis, it is possible that the reagents may be retained by the Ghost Buster column, impacting the analysis retention time and peak shape.
  2. Amines additives - If amines additives, such as ammonia and triethylamine, are used in the solvent the peakshape may change.
Note:
  1. It should be noted that not all impurities can be removed from the mobile phase.
  2. It is not recommended to flush the Ghost Buster column with 100% water for a long time.
  3. GhostBuster column is installed between the gradient mixer and the sampler. If it is installed like a guard column, target peaks may disappear.
  4. GhostBuster column’s service life differs by analysis conditions, mobile phase and its purity.
  5. New column is recommended when result is not ideal.
 
Sr no.

Part No

Dimensions

1

SFT.GSTB.4650

50mmX4.6mm

2

SFT.GSTB.4630

30mmX4.6mm

3

SFT.GSTB.4621

50mmX2.1mm

4

SFT.GSTB.3021

30mmX2.0mm

Customized dimension can be made available on customer request, subject to the availability.

Introduction

  • Sifto Ghost Buster Column can very efficiently absorb the impurities from mobile phase and eliminates the risk of ghost peaks interfering with target peaks and make the gradient analysis reliable.
  • Longer Column life (Main column) when used with Sifto Ghost Buster Column.
  • Stable over a wide range of pH, organic solvents and aqueous buffers.
  • Add Graphs

Advantages & limitations

Advantages 

  1. Remove ghost peaks efficiently
  2. Compatible with water and organic solvents
  3. Easy to install
  4. Trace detection
  5. Can be used multiple times                   

Limitations

  1. Ionparing solvent – If ion pairing reagents are used in the analysis, it is possible that the reagents may be retained by the Ghost Buster column, impacting the analysis retention time and peak shape.
  2. Amines additives – If amines additives, such as ammonia and triethylamine, are used in the solvent the peakshape may change.                                                  

Note:

    1. It should be noted that not all impurities can be removed from the mobile phase.
    2. It is not recommended to flush the Ghost Buster column with 100% water for a long time.
    3. GhostBuster column is installed between the gradient mixer and the sampler. If it is installed like a guard column, target peaks may disappear.
    4. GhostBuster column’s service life differs by analysis conditions, mobile phase and its purity.
    5. New column is recommended when result is not ideal.

Ordering Info

Sr no.

Part No

Dimensions

1

SFT.GSTB.4650

50mmX4.6mm

2

SFT.GSTB.4630

30mmX4.6mm

3

SFT.GSTB.4621

50mmX2.1mm

4

SFT.GSTB.3021

30mmX2.0mm